Cosytoes Wireless Timerstat Installation Instructions
Features.
The Cosytoes Programmable Wireless Timerstat consists of a mobile transmitter unit and a receiver unit. The flush-mounting receiver unit will fit most 60mm conduit boxes. The installation requires no wiring between transmitter and receiver and can be fitted in any normal operating environment within a 30m range between the two units. A unique facility of this device is its R/F address code setting, which is built into both the transmitter and the receiver to ensure that the R/F signal will not be interfered by any other nearby R/F signal. A maximum heat selector switch is built inside the receiver to provide installers with aneasy means to set a required floor temperature limit. The blue backlit display and buttons of the transmitter allow for operation even in dim lighting. There is a choice of three working frequencies. ‘Frequency’ is marked on the top right of the plastic housing on both the transmitter and receiver. The marked frequency on both units must be consistent or the transmitter and receiver will not operate.

The transmitter unit is powered by 4xAAA alkaline batteries. Two batteries to power the transmitter and another two to power the backlit display and red L.E.D. The receiver unit uses mains power for operation.
Technical Data.
- Power supply : 1.5 V AAA Battery x 4 2 pieces each for Transmitter-uint’s operating and back light
- Battery: 1 year
- Temperature reading : °C /°F selective by internal setting
- Clock format : 24H/12H selective by internal setting
- Temperature sampling rat e : 1 minute
- Switching differential : 0.5°C~1.0°C / 1.0°F~2.0°F selective by internal setting
- Temperature control range : 5~35°C
- Temperature display range : 0~50°C
- Temperature setting: 1.0
- Programming feature: 7-d or 5-1-1d day-format & P6/P4 program-periods/day by default setting, not selective at user’s side.
- Shortest cycle rate protection : 3-minute, default setting “deactivated”.
- Non volatile EEPROM ensures no program/setting loss
- Temperature sensor: 100K Ω at 25 °C
- Working Frequency: 3 types for option (installer preset, not selective by users)
T433 : 433.92 MHZ
T868 : 868.35 MHZ
T915 : 915 MHZ
- R/F signal transmission cycle : transmits 3 times in cycle of 2.5 minutes,continuous.
- Working distance : 30 meters
- Dimension :110.8 W x 104 H x21.5 D mm.
Receiver Unit RVF-0356 RX (R433~R868~R915)
- Operating power: 230Vac 50/60Hz
- Power consumption ␣5VA
- Output rating:16 Amp/25␣0Vac resistive, Volt-free
- Storage temperature: -10°C ~ 60°C
- Working frequency : a-433.92MHz b-868.35MHz c-915MHz
- Working distance : 30 Meters
- Floor sensor: 10K Ω at 25°C
- Floor temperature limitation setting range : 26°C~40°C
- Switching differential in floor temperature limitation : 2.0°C. Prefixed
- Installation : 60 mm flush-mount
- Dimension : 88.0 W x 88.0 H x 39.4 D mm
IMPORTANT: All electrical work should be carried out by a qualified electrician and comply with I.E.E. regulation.
Product Description: Transmitter Unit.
Product Description: Receiver Unit.
Fixing the Plug-in stand on Transmitter unit.
Insert “-" head screw-driver into position shown here.
Push upward
Pull stand off back plastic housing
Hold the stand with hand, press it vertically against the “groove” originally is to store the stand.
Note: Make sure the “stand” faces to correct direction.
Glide the "stand" downward.
The stand is now fixed
Pressing “stand” downward, as shown in picture above, can take it off from back housing.
Installing/replacing batteries in the Transmitter-unit.
Opening the Transmitter Unit Assembly (to access the Frequency Selector).
Note: Flat-head screw-driver required as assisting tool.
Insert screw-driver as shown in picture
Tilting downward to loosen the "hook-on" enclosure.
Open as shown.
Reassembling the Transmitter Unit Assembly (after access the Frequency Selector).
Note: Flat-head screw-driver required as assisting tool.
Replace the "hook-on" enclosure as shown in picture.
Press to firmly close.
To Open the Receiver Unit.
Note: "+" head screw-driver required as assisting tool.
Slacken the fastening screw as shown.
Take appart the housing.
To Reassemble the Receiver Unit.
Note: "+" head screw-driver required as assisting tool.
The stud on the front housing fits into the square-hole on the rear assembly.
Close the two parts and line up the “groove” with the screw, as shown.
Tighten the screw.
RF Address Code Setting.
On the back of the Transmitter circuit board.
If there is another RVF-0356 unit nearby, e.g in the next house, the receiver may be fault triggered by the other transmitter.You may select a different RF address code to prevent this. Receiver can only response to RF coding with the same address code setting as its own address code.
Set the selection the same way on both frequency selection switches.
Setting the Floor temperature limitation.
Wiring Diagram.
The heating system should be protected by an RCD to comply with the terms of guarantee and to be fully I.E.E. compliant. The receiver unit must be installed outside a bathroom. This device is rated at: - 16amps/3500w or 22sqm Cosytoes mat @ 160w/sqm.
Important Note (By FCC, for application of 915 MHz.)
To comply with the FCC RF exposure compliance requirements ,no change to the antenna or the device could result in the device exceeding the RF exposure requirements and void user’s authority to operate the device. This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions (1)this device may not cause harmful interference, and (2)this device must accept any interference received,including interference that may cause undesired operation.